Indicator Settings
  1. NumberShowTitleMinMaxValueSuffixTypeFunctionRegister
Function:
Coil 1 ... Coil 8 - discrete outputs R1-R8, if any.
Coil0 ... Coil23 - flags F0 - F23.
DI 1 ... DI 8 - discrete inputs 1 to 8.
HR 100 ... HR 2670 - scripts.
HR 2980 ... HR 2995 - access to timers TIMER0 - TIMER15.
IR 1 ... IR 8 - ADC value of inputs 1 to 8.
IR 11 ... IR 18 - input values after recalculation from 1 to 8.
IR 20 ... IR 999 - intermediate variables.
HR 3000 ... HR 3999 - access to variables IR 0 ... IR 999.
IR 9004 ... IR 9007 - Date.
IR 9008 ... IR 9010 - Time.
IR 9011 ... IR 9016 - Identifier.
IR 9020 - Random number.
The rest are not available.
For type "Frame" - link: "https://[Title][Suffix]"
Description:
The Show field allows you to show or hide a component.
Title can be written in Latin or Cyrillic, the maximum length is 24 characters.
Min and Max values in the range -32768 +32767.
Value is an input parameter.
Suffix value label, max length 10 characters:%, °C, Lux, m²/s. To display decimal values, enter a divisor and a semicolon, for example: 0.01;°C (there will be values 0.01°C) or 100;°C (there will be values of 100°C).
Type version of the indicator.
Function and Register is the source of data from the Modbus protocol.